FIBARO FGPB-101 Operating Manual - Page 5
Browse online or download pdf Operating Manual for Controller FIBARO FGPB-101. FIBARO FGPB-101 8 pages. Fibaro button
Also for FIBARO FGPB-101: Operating Manual (15 pages), Instructions Manual (6 pages), Operating Manual (15 pages)
8
#5: Associations
Association (linking devices) - direct control of other devices within
i
NOTE
the Z-Wave system network e.g. Dimmer, Relay Switch, Roller Shutter
Association
ensures
or scene (may be controlled only through a Z-Wave controller).
direct
transfer
of
control
commands
between devices, is
performed
without
The Button provides the association of four groups:
participation of the
1st association group – "Lifeline" reports the device status and al-
main controller and
lows for assigning single device only (main controller by default).
requires
associated
device to be in the di-
2nd association group – "On/Off" is assigned to clicking the button
rect range.
and is used to turn on/off associated devices.
3rd association group – "Dimmer" is assigned to holding the but-
i
NOTE
ton and is used to change level of associated devices.
The device supports
4th association group – "Alarm" is assigned to clicking and/or hold-
the generic Z-Wave
ing the button (triggers are defined in parameter 30) and is used to
command class "Basic"
send alarm frames to associated devices.
but will ignore any SET
or GET commands and
will not respond with a
Basic Report.
FIBARO Button in 2nd, 3rd and 4th group allows to control 5 regular
or multichannel devices per an association group, with the exception
i
NOTE
of "LifeLine" that is reserved solely for the controller and hence only 1
Increasing
number
node can be assigned.
of associations will
It is not recommended to associate more than 10 devices in general,
increase battery con-
as the response time to control commands depends on the number of
sumption resulting in
associated devices. In extreme cases, system response may be delayed.
shorter battery life.
To add an association (using the home Center controller):
1. Go to device options by clicking the icon:
2. Select the „Advanced" tab.
3. Click the "Setting Association" button.
4. Specify to which group and what devices are to be associated.
5. Save the changes.
6. Wake up the device manually to confirm changes (4 clicks).
ASSOCIATIOnS
#6: Advanced parameters
The Button allows to customize its operation to user's needs. The set-
tings are available in the FIBARO interface as simple options that may
be chosen by selecting the appropriate box.
In order to configure the Button (using the hC controller):
1. Go to the device options by clicking the icon:
2. Select the „Advanced" tab.
3. Modify values of chosen parameters.
4. Save the changes.
5. Wake up the device manually to confirm changes (4 clicks).
Wake up interval
Available settings: 0 or 3600-64800 (in seconds, 1h - 18h)
Default setting: 0
The Button will wake up at each defined time interval and always try to
connect with the main controller. After successful communication at-
tempt, the device will update configuration parameters, associations
and settings and then will go into Z-Wave communication standby.
After failed communication attempt (eg. no Z-Wave range) the device
will go into Z-Wave communication standby and retry to establish
connection with the main controller after the next time interval.
Setting wake up interval to 0 disables sending Wake up notification
to the controller automatically. Wake up may be still performed man-
ually by clicking the Button 4 times.
1. Scenes sent to the controller
This parameter determines which actions result in sending scene IDs
and attributes assigned to them.
Available settings: 1 - Key Pressed 1 time
2 - Key Pressed 2 times
4 - Key Pressed 3 times
8 - Key Pressed 4 times
16 - Key Pressed 5 times
32 - Key held Down
64 - Key Released
Default setting:
127 (all)
Parameter size:
9
i
NOTE
Longer wake up time
interval means less
frequent communica-
tion and thus a longer
battery life.
i
NOTE
values of parameter
1 may be combined,
e.g. 1+2=3 means that
scenes will be sent
after pressing the but-
ton once or twice.
1 [byte]