#3: Adding/removing the device

Adding (Inclusion) - Z-Wave device learning mode, allowing to add
i
NOTE
the device to existing Z-Wave network.
Adding
in
Security
To add the device to the Z-Wave network:
Mode must be per-
formed up to 2 meters
1. Place the Button within the direct range of your Z-Wave controller.
from the controller.
2. Set the main controller in (Security/non-Security) add mode (see
the controller's manual).
i
NOTE
3. Click the Button at least six times.
4. Wait for the adding process to end.
In case the device is
not added, repeat the
5. Successful adding will be confirmed by the Z-Wave controller's
adding procedure.
message.
Removing (Exclusion) - Z-Wave device learning mode, allowing to
i
NOTE
remove the device from existing Z-Wave network.
Removing the Button
To remove the device to the Z-Wave network:
from the Z-Wave net-
work restores all the
1. Place the Button within the direct range of your Z-Wave controller.
default parameters of
2. Set the main controller in remove mode (see the controller's
the device.
manual).
3. Click the Button at least six times.
4. Wait for the removing process to end.
5. Successful removing will be confirmed by the Z-Wave controller's
message.
ADDInG/REMOvInG ThE DEvICE

#4: Operating the device

Operating the Button:
1 click:
send action to associated devices (switch on/off by de-
fault) and/or trigger a scene
2 clicks:
send action to associated devices (switch on maximum
level by default) and/or trigger a scene
3 clicks:
send action to associated devices (no action by default)
and/or trigger a scene
4 clicks:
wake the device up and/or trigger a scene
5 clicks:
start reset procedure (press and hold for 5s to confirm)
and/or trigger a scene
6 or more
learning mode (adding/removing)
clicks:
Hold:
send action to associated devices (start level change up/
down) and/or trigger a scene
Release:
send action to associated devices (stop level change)
and/or trigger a scene
Waking up the device:
The Button needs to be woken up to receive information about the
new configuration from the controller, like parameters and associa-
tions.
Click the Button 4 times to wake it up.
Scene ID:
Action
Every
action
with
the
1 click
Button is send to the main
2 clicks
controller with Scene ID
3 clicks
equal to 1. Controller recog-
4 clicks
nizes type of action using the
attribute assigned to it.
5 clicks
hold
Release
Reset procedure of the Button:
Reset procedure allows to restore the device back to its factory set-
tings, which means all information about the Z-Wave controller and
user configuration will be deleted. In order to reset the device:
1. Click the Button exactly five times.
2. Press and hold the Button for at least 5 seconds.
i
NOTE
If
notifications
are
enabled, each press
of the button results
in sending a com-
mand
(notification
Type=hOME_SECuRI-
TY,
Event=Intrusion,
unknown Location).
Attribute
Key Pressed 1 time
Key Pressed 2 times
Key Pressed 3 times
Key Pressed 4 times
Key Pressed 5 times
Key held Down
Key Released
OPERATInG ThE DEvICE