Cisco UCS B200 M3 Installation And Service Note - Page 17
Browse online or download pdf Installation And Service Note for Server Cisco UCS B200 M3. Cisco UCS B200 M3 28 pages. Blade server
Also for Cisco UCS B200 M3: Installation Manual (34 pages), Installation And Service Note (36 pages), Installation And Service Note (37 pages), Manual (8 pages), Upgrade Manual (21 pages)
Figure 13: Using the CPU Pick and Place Tool to Insert the CPU
1
Step 6
Close the socket latch. See callout 1 in the following figure.
Step 7
Secure the first hook, which has the following icon: See callout 2 in the following figure.
Step 8
Secure the second hook, which has the following icon:
Figure 14: Replacing the Heat Sink (B200 M3 Shown)
Step 9
Using the syringe of thermal grease provided with replacement CPUs and servers, add 2 cubic centimeters of thermal
grease to the top of the CPU where it will contact the heat sink. Use the pattern shown. This should require half the
contents of the syringe.
Caution
The thermal grease has very specific thermal properties. Thermal grease from other sources should not be
substituted because it may lead to damage.
Alignment mark on the tool
button/handle
2
See callout 3 in the following figure.
Alignment mark on the CPU
socket
17