Cisco UCS B200 M4 Servicing Manual - Page 14

Browse online or download pdf Servicing Manual for Server Cisco UCS B200 M4. Cisco UCS B200 M4 24 pages. For e5-2600 v4 series cpus
Also for Cisco UCS B200 M4: Installation And Service Note (30 pages), Installation And Service Note (46 pages), Upgrade Manual (9 pages)

Cisco UCS B200 M4 Servicing Manual

Installing Memory

Installing Memory
To install a DIMM into the blade server, follow these steps:
Procedure
Step 1
Open both DIMM connector latches.
Step 2
Press the DIMM into its slot evenly on both ends until it clicks into place.
DIMMs are keyed. If a gentle force is not sufficient, make sure the notch on the DIMM is correctly aligned.
Note
Step 3
Press the DIMM connector latches inward slightly to seat them fully.
Supported DIMMs
Do not use any memory DIMMs other than those listed in the specification sheet. Doing so may irreparably
damage the server and require down time.
Memory Population
The blade server contains 24 DIMM slots—12 for each CPU. Each set of 12 DIMM slots is arranged into
four channels, where each channel has three DIMMs.
Figure 12: Memory Slots In the Blade Server
1
Servicing a Blade Server
14
Be sure that the notch in the DIMM aligns with the slot. If the notch is misaligned you may damage
the DIMM, the slot, or both.
Channels A-D for CPU 1
2
Channels E-H for CPU 2
Servicing a Blade Server