DESCRIPTION AND USE OF HOOD
Control panel
1. OFF / Extraction speed (power) decrease button
2. ON / Extraction speed (power) increase button
Note: The intensive extraction speed (power) is timed and lasts for 5
minutes (indicator c flashes); the hood then reverts to extraction speed
(power) 2.
3. ON/OFF Timer button: delays the deactivation of the selected extraction speed (power) by 5 minutes.
Note: the button is also used for the "Filter saturation signal reset " function
4. Light ON/OFF button
5. Display, shows:
a. Extraction speed (power): the indicator rotates according to the selected extraction speed (power).
Safety operation: the indicator flashes.
b. Grease filter saturation: comes on when filter maintenance is required.
c. Timer
d. Active carbon filter saturation: comes on when filter maintenance is required.
Note: this function is normally disabled and should only be activated if he hood is used as a filter version (with carbon filter fitted).
To do so, proceed as follows:
- switch off the hood
- press and hold buttons 1 and 3 at the same time, until the indicator stops flashing (indicator disabled) and is lit steadily (indicator
enabled).
- release the buttons.
To deactivate it, repeat the procedure: the indicator will no longer be lit steadily (indicator enabled) and will flash instead (indicator
disabled).).
e. Lighting
Safety operation
The hood has a sensor which, in the event of a sudden increase in temperature, activates the appliance until the temperature drops
significantly.
Filter saturation signal reset
After carrying out filter maintenance, press and hold button 3 until indicator switched off.
1. Control panel.
2. Extraction panel.
3. Grease filters.
4. Halogen lamps.
GB10