Whirlpool AKR8551IX Kullanım ve Bakım Kılavuzu - Sayfa 10

Havalandırma Davlumbazı Whirlpool AKR8551IX için çevrimiçi göz atın veya pdf Kullanım ve Bakım Kılavuzu indirin. Whirlpool AKR8551IX 16 sayfaları.

Whirlpool AKR8551IX Kullanım ve Bakım Kılavuzu
DESCRIPTION AND USE OF HOOD
Control panel
1. OFF / Extraction speed (power) decrease button
2. ON / Extraction speed (power) increase button
Note: The intensive extraction speed (power) is timed and lasts for 5
minutes (indicator c flashes); the hood then reverts to extraction speed
(power) 2.
3. ON/OFF Timer button: delays the deactivation of the selected extraction speed (power) by 5 minutes.
Note: the button is also used for the "Filter saturation signal reset " function
4. Light ON/OFF button
5. Display, shows:
a. Extraction speed (power): the indicator rotates according to the selected extraction speed (power).
Safety operation: the indicator flashes.
b. Grease filter saturation: comes on when filter maintenance is required.
c. Timer
d. Active carbon filter saturation: comes on when filter maintenance is required.
Note: this function is normally disabled and should only be activated if he hood is used as a filter version (with carbon filter fitted).
To do so, proceed as follows:
- switch off the hood
- press and hold buttons 1 and 3 at the same time, until the indicator stops flashing (indicator disabled) and is lit steadily (indicator
enabled).
- release the buttons.
To deactivate it, repeat the procedure: the indicator will no longer be lit steadily (indicator enabled) and will flash instead (indicator
disabled).).
e. Lighting
Safety operation
The hood has a sensor which, in the event of a sudden increase in temperature, activates the appliance until the temperature drops
significantly.
Filter saturation signal reset
After carrying out filter maintenance, press and hold button 3 until indicator switched off.
1. Control panel.
2. Extraction panel.
3. Grease filters.
4. Halogen lamps.
GB10