Dixon Bayco FloTech FT208 Manual - Page 14
Browse online or download pdf Manual for Monitor Dixon Bayco FloTech FT208. Dixon Bayco FloTech FT208 20 pages. Checkmate programmable retain / overfill onboard monitor
A PERMIT signal will be issued if:
All the sensor inputs that have been programmed as active see dry sensor signals.
Any of the Retain sensors are wet and the Retain Reset pushbutton has been pressed.
All the sensor inputs that have been programmed as inactive see no signals.
The AUX input is jumpered or made through an external set of contacts.
A PERMIT signal will NOT be issued if:
Any of the sensors that have been programmed as active are wet or are not connected.
Any of the sensors that have been programmed as inactive see a sensor signal.
The AUX input is not jumpered or made through an external set of contacts.
Retain Sensor Override
Should a driver wish to load over retained product, such as splash blending, the driver must do the following:
1. Connect the API plug from the rack to the optic or thermistor socket on the trailer. The monitor will be
in a non-permissive state (Green Permit led will be off).
2. Press the Retain Reset switch. The monitor is now in a permissive state (Green Permit led will be on)
and a permit load signal will be sent to the loading rack.
3. The monitor will remain in a permissive state until the API plug is removed from the trailer socket.
Then the monitor will switch to a non-permissive state and prevent future loading until the API plug is
again connected to a rack.
FloTech Programmable CheckMate Retain / Overfill Monitor
14
10466 REV N
FT208 CheckMate