CYP CMIR-882 Operation Manual - Page 10

Browse online or download pdf Operation Manual for Matrix Switcher CYP CMIR-882. CYP CMIR-882 20 pages. 8x8 bi-directional infrared matrix

Source Out All: Connect to a single IR blaster cable for IR signal
transmission, IR signals will be relayed from all TV outputs (A~H)
at the same time. Place the IR blaster in direct line-of-sight of the
equipment to be controlled.
5
DC 5V: Plug the 5V DC power supply into the unit and connect the
adaptor to an AC outlet.

6.3 Remote Control

The remote control's settings can be controlled
with the four DIP switches on the back of the unit
(under the battery compartment cover). When
all the DIP switches are set to ON (
remote control is able to control all the input
settings for all outputs. For example, to set Output
A to relay commands from Input 5 press Button
A to select Output A and then press Button 5 to
select Input 5, Output A will switch to Input 5.
The Remote Control can also be set to limit the
Input selection to only one Output, allowing
different remote control units to perform input
selection individually for each output port i.e. a
single zone (refer to Section 6.6 - IR Custom codes
and DIP switch Settings for details). For example,
when all DIP switches are set to OFF (
this setting limits input selections to only Output A.
Therefore, when setting Output A to input 3 only Button 3 needs to be
pressed to switch to that input.
5
) the

),

1
A
2
B
3
C
4
D
5
E
6
F
7
G
8
H
IN
OUT