Doug Fleenor Design DMX24DIM-2U Installatie- en bedieningshandleiding - Pagina 4
Blader online of download pdf Installatie- en bedieningshandleiding voor {categorie_naam} Doug Fleenor Design DMX24DIM-2U. Doug Fleenor Design DMX24DIM-2U 5 pagina's.
Setting the address switches
The front panel address switches are used to select the DMX512 starting address for the DMX24DIM
or DMX24DIM-2U. Any starting address from 1 - 512 can be selected. The address shown on the
switches will be the DMX512 address for the first dimmer output. The next 23 consecutive DMX512
levels will be applied to the remaining dimmer channels.
When the address switches are set to 000, the DMX24DIM or DMX24DIM-2U operates as if the
address switches were set to 001.
The address switches are also used for a local test function described below.
Local control
Local control mode is used to turn on an output without the use of a DMX512 signal source. To use
local control, set the DMX address switches to 601 to turn on channel 1, 602 for channel 2, etc.
LED indicators
The LED indicators on the front of the DMX24DIM or DMX24DIM-2U have the following functions:
LED label
Function
SIGNAL
On when DMX is present, flashes when local control is active
MIMIC 1
Tracks the current level of dimmer 1 for troubleshooting purposes
PWR
On when power is on
Loss of DMX512 signal
Upon loss of the DMX512 input, the DMX24DIM will begin fading all of its outputs to zero. The fade
out time is about 60 seconds from the loss of signal.
Page 4 of 5