DUCTFORMER TDFC Bedienings- en procedurehandleiding - Pagina 8

Blader online of download pdf Bedienings- en procedurehandleiding voor {categorie_naam} DUCTFORMER TDFC. DUCTFORMER TDFC 12 pagina's. Power brake

OPERATING and PROCEDURES MANUAL
TDFC POWER BRAKE
Button Description
The electrical enclosure has all of the main control selectors and buttons to operate the
system. The following is a description of their individual functions.
POWER ON/OFF – This selector switch with green light indicates that power is supplied
to the machine and ready for operation
CYCLE START (FOOT PEDAL): – This foot switch controls the automatic feed cycle of
the Power Brake operation. When depressed, the press bar will come down to clamp
the part in place, next the folder will swing up. After this operation the folder will swing
back down and the press bar will retract. Machine must be selected to AUTO mode.
MANUAL/AUTO: - This selector switch will set the desired operation mode for the
machine. Manual mode must be selected for the various manual push button
operations. Automatic mode must be selected when running production.
PRESS DOWN – This push button operates simultaneously with the MANUAL CLAMP
button to operate the press bar. Press and hold the PRESS DOWN button until the
press is run all the way down; then without releasing simultaneously press the
MANUAL CLAMP button to hold the press in the clamping position. After releasing
both buttons press the PRESS DOWN button again to move the press back to the up
position. Machine must be selected to MANUAL mode.
Page 8 of 12