Once the Flushvalve is installed re­connect the
7
water supply and ensure that the cistern fills
correctly and that there are no leaks.
Maximum water level
The maximum water level must be below
the top of the overflow pipe. This is usually
controlled by an inlet valve operated by a
float.
It is recommended that the maximum water
level is set up now at this stage.
Minimum water level ­ IMPORTANT
The minimum water level after flush cycle
finishes must be 5mm above the Flushvalve
window. It is very important that the minimum
water level does not fall below this level.
If the level falls below this point the valve
operation will be more audible and you also
risk damaging the valve.
The minimum water level is controlled by the
flush time on the control system (covered later
in section 9 of these instructions).
It is recommended that tuning of the minimum
water level is left until section 9 where flush
time settings are explained in more detail.

MINIMUM LEVEL

Key (Right):
1.
MAX Water level (controlled by float
switch)
2.
MIN Water level (controlled by flush time)
3.
Top of Flushvalve window
220-240V a.c
Flushvalve WC Flushing System Instructions ­ Version INFL002 v2.0 180511
5mm
1
2
3