DVS D103/V2/AUTO Handleiding voor installatie en gebruik - Pagina 6

Blader online of download pdf Handleiding voor installatie en gebruik voor {categorie_naam} DVS D103/V2/AUTO. DVS D103/V2/AUTO 8 pagina's. Flushvalve wc flushing system with the fully automatic sensor

Connector plugs
8
The connector plugs can be disconnected
from the mating sockets when wiring external
equipment, double check positions with the
plug orientations as they only fit one way!
Cable glands
Fit the Flushvalve cable through gland. Tighten
until rubber touches the cable completely and
then tighten with a further ½ turn (180°).
Cable connection
The Flushvalve cable should be trimmed to
length and connected to the control box.
Connect the Blue wire to the Blue terminal,
Brown wire to the Brown terminal. Please
check the cable is clean and dry before
connection onto the PCB.
When each plug has been wired the cables
can be pulled back through the cable
glands, and the plug re­connected to the
corresponding socket. Cables should not be
left to tort or slack.
220-240V a.c
This sensor is designed to operate as part of a
9
flushvalve control system, which incorporates a
flushvalve, control unit and power supply. This
sensor should only be used with the supplied
control unit.
The Auto Flushvalve Sensor is designed to flush
the toilet as the user leaves the area.
The sensor should be fitted centrally above
the WC Pan at a height where the bottom of
the sensor is approximately 30mm from the
top of the raised toilet seat. The sensor should
be orientated with the 'pot' at the 9 o' clock
position.
If the sensor is fitted to a brick wall you may
require a thread extension. Please contact
DVS to purchase an extension and advise the
wall thickness.
With the power disconnected the sensor is
wired to the Automatic Sensor position in the
control box. See section 3 board layout. If the
sensor is fitted to a brick wall you may require
a thread extension. Please contact DVS to
purchase an extension and advise the wall
thickness.
220-240V a.c
Flushvalve WC Flushing System Instructions ­ Version INFL002 v2.0 180511
Key (Below):
1.
Flushvalve cable
2.
Flushvalve connector plug
3.
Flushvalve input
4.
Control box lid
Safety
CAUTION! 220­240V a.c.
NEVER open the cover with the supply live.
DO NOT extend cables.
DO NOT leave badly fitted cables.
DO NOT leave slack cables in the
enclosure.
DO NOT interfere with the mains flex.
DO check all cables and connections.
DO ask for advice if/when necessary.
Correct positioning
30mm from the top of the
raised toilet seat, aligned
to the centre of the users
back.
Incorrect positioning
If the sensor if positioned
too high there is a strong
possibility the user will exit
the sensing area when
moving their head, causing
the sensor to falsely trigger
the flush
Page 5
1
2
3
4