CORNING EDC-02P-NH Handmatig - Pagina 2

Blader online of download pdf Handmatig voor {categorie_naam} CORNING EDC-02P-NH. CORNING EDC-02P-NH 7 pagina's. Environmental distribution center
Ook voor CORNING EDC-02P-NH: Handmatig (12 pagina's)

CORNING EDC-02P-NH Handmatig
4.

HOUSING PREPARATION

Step 1:
Open housing door with slotted screwdriver.
Step 2:
remove base plate from housing with phillips-head screwdriver.
Step 3:
mark and drill holes in bottom of housing according to drawings.
EDC-02P-NH
2 in
1.75 in
(5 cm)
(4 cm)
2.75 in
(7 cm)
Step 4:
Install Cable entry port Fittings according to the instructions provided with them.
Step 5:
reinstall the base plate with the phillips-head screwdriver.
Step 6:
to make cable installation easier in the -06p and the -12p units, remove the splice tray
holder by sliding it towards the top of the housing and lifting it out.
5.
MOUNT THE HOUSING TO A WALL OR POLE
Step 1:
remove the stabilizer bracket.
NOTE:
If you will be mounting the eDC without the stabilizer bracket, discard
it at this time. rotate the top bracket of the eDC-02p-NH (not necessary
on -06p and -12p) so the elliptical hole is exposed. position the housing
as desired and secure using ¼-inch screws in the top and bottom
mounting brackets.
Step 2:
Drive ¼-inch screws or wall anchors through the stabilizer
bracket and into the mounting surface. Do not install a screw
in the bottom hole of the stabilizer bracket at this time.
Step 3:
Hang the eDC on the stabilizer bracket, making sure that the
top mounting bracket is resting between the two tabs on the
stabilizer bracket.
Step 4:
Line up the elliptical hole in the bottom mounting bracket
with the bottom hole in the stabilizer bracket and drive a
¼-inch screw or wall anchor through the brackets and into
the mounting surface.
6.

CABLE PREPARATION

Step 1:
Route the feeder cable through the fitting on the left at the
base of the unit.
Step 2:
Access the cable according to the following distances leaving 2.5 inches of central member
and 4 inches of yarn, if present:
EDC-02P-NH: 6 ft (2 m)
STANDARD RECOMMENDED PROCEDURE 003-304 | ISSUE 10 | September 2010 | PAGE 2 OF 7
EDC-06P-NH
2.25 in
(6 cm)
2.25 in
1.375 in
(6 cm)
(3.5 in)
TPA-2906
7 in
2.625 in
(18 cm)
1.375 in
(6.7 cm)
(3.5 cm)
EDC-06P-NH: 10 ft (3 m)
EDC-12P-NH
2.25 in
(6 cm)
1.75 in
1.25 in
(4 cm)
(3 cm)
6.25 in
(16 cm)
TPA-2907
Stabilizer
Bracket
Hang the unit over the
mounted stabilizer bracket.
EDC-12P-NH: 15 ft (5 m)
2.25 in
(6 cm)
1.75 in
1.25 in
(4 cm)
(3 cm)
3.50 in
1.375 in
(9 cm)
(3.5 cm)
TPA-2905
TPA-2908
TPA-2909
Drive a screw through the mounting
bracket and stabilizer bracket and
into the mounting surface.