CORNING FBC-015 Technische instructies - Pagina 6
Blader online of download pdf Technische instructies voor {categorie_naam} CORNING FBC-015. CORNING FBC-015 6 pagina's.
Problem: Error light flashes
Possible Cause:
1. Ferrule Adapter maybe dirty
à
2. The connector may be dirty
à
3. The photo detector is dirty
4. The connector is not loaded
correctly à
5. The ferrule adapter is not
properly secured in the adapter
à
port
à
6. Weak Batteries
C o r n i n g C a b l e S y s t e m s G m b H & C o . K G · L e i p z i g e r S t r . 1 2 1 · 1 0 1 1 7 B e r l i n , G e r ma n y
T E L : 0 0 8 0 0 - 2 6 7 6 - 4 6 4 1 ( 0 0 8 0 0 - C O R N I N G 1 ) · F A X : + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5 · E m a i l : e me a . c s @ c o r n i n g . c o m
w w w . c o r n i n g . c o m/ c a b l e s y s t e ms
Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems' products without prior notification. LANscape
is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. ©
2007 Corning Cable Systems. All rights reserved. Published in the EU.
Solution:
1. Clean the Ferrule Adapter and connector. The adapter is
cleaned by the cleaning sticks provided in the tool. Insert
stick into the adapter opening and rotate the stick 10 times,
clockwise (apply varying pressures to create a pumping
action). Don' t reuse the stick.
2. Clean the end face of the connector.
3. Clean the photo detector with a dry wipe.
à
4. Remove connector dust caps. The date code on the SC and
LC should be facing up. The " UP" of the ST adapter should
be facing up. The crimp tube must protrude past the crimp
arms.
5. Make sure the proper ferrule adapter is being used and is
fully seated on the connector.
6. Replace batteries
Techni cal Instructi ons
Oc t ober 19, 2007
Photo
Detector