Olympus BH2 Series Handmatig - Pagina 2
Blader online of download pdf Handmatig voor {categorie_naam} Olympus BH2 Series. Olympus BH2 Series 6 pagina's. Phase contrast
Ook voor Olympus BH2 Series: Handleiding voor probleemoplossing en afstelling (46 pagina's), Volledige demontage, reiniging en hermontage (23 pagina's), Volledige demontage, reiniging en hermontage (40 pagina's), Demontage, reiniging en hermontage (45 pagina's), Installatiehandleiding (9 pagina's)
Introduction ............................................................................................................................................................................ 3
Scope of this Document ...................................................................................................................................................... 3
What is Phase Contrast? ......................................................................................................................................................... 3
How Does Phase Contrast Work? ........................................................................................................................................... 3
Phase Contrast Types .............................................................................................................................................................. 3
Setting Up for Phase Contrast Microscopy ............................................................................................................................. 3
Match Selector Dial with the Low-Power Objective ........................................................................................................... 4
Replace Eyepiece with Phase-Centering Telescope ............................................................................................................ 4
Focus the Phase-Centering Telescope ................................................................................................................................ 4
Center the Selected Phase Annulus .................................................................................................................................... 5
Center the Remaining Phase Annuli ................................................................................................................................... 5
Replace Centering Telescope with the Eyepiece ................................................................................................................ 5
Place Green/Yellow Filter into Filter Receptacle ................................................................................................................ 5
Using Phase Contrast .............................................................................................................................................................. 6
Periodically Verify Centering of the Phase Annuli .............................................................................................................. 6
About the Phase Contrast Filter .......................................................................................................................................... 6
Phase Contrast Artifacts .......................................................................................................................................................... 6
How To Contact the Author .................................................................................................................................................... 6
Figure 1 - Set condenser dial to match the objective ............................................................................................................ 4
Figure 2 - Replace right eyepiece with phase telescope ........................................................................................................ 4
Figure 3 - Phase telescope improperly focused ..................................................................................................................... 4
Figure 4 - Adjust knurled focus ring to focus the image ........................................................................................................ 4
Figure 5 - The phase telescope is properly focused ............................................................................................................... 4
Figure 6 - Centering screws of BH2-PC/PCD condenser ......................................................................................................... 5
Figure 7 - The phase ring and phase annulus images ............................................................................................................ 5
Figure 8 - The phase annulus properly centered ................................................................................................................... 5
Figure 9 - Place green/yellow filter into filter receptacle ...................................................................................................... 6
Phase Contrast on the Olympus BH-2 Microscopes
Table of Contents
Table of Figures
Revision 1
Page 2 of 6