Cisco UCS B200 M3 Handmatig - Pagina 3

Blader online of download pdf Handmatig voor {categorie_naam} Cisco UCS B200 M3. Cisco UCS B200 M3 8 pagina's. Blade server
Ook voor Cisco UCS B200 M3: Installatiehandleiding (34 pagina's), Installatie en onderhoud (36 pagina's), Installatie en onderhoud (37 pagina's), Upgrade handleiding (21 pagina's), Installatie en onderhoud (28 pagina's)

Cisco UCS B200 M3 Handmatig

Install fNIC Drivers

This guide assumes that the UCS 2 .1 .2a or later fNIC drivers have been installed and are running . Please see the Cisco
UCS Manager Install and Upgrade Guides, Virtual Interface Card Drivers section, for complete driver installation instructions:
http://www .cisco .com/c/en/us/support/servers-unified-computing/ucs-manager/products-installation-guides-list .html
In addition, please review the Cisco UCS Hardware Compatibility List (HCL) to confirm hardware, operating system, and driver
compatibility:
http://www .cisco .com/en/US/products/ps10477/prod_technical_reference_list .html

Configuring fNIC Tunables

LUN Queue Depth

Description: The total number of I/O requests that can be outstanding on a per-LUN basis .
Parameter name: fnic_max_qdepth
Default value: 32
Configuration capabilities:
• Boot Time
» Requires reboot for changes to take effect .
» Changes are persistent across reboots .
• Load Time
» Disruptive to SAN attached storage .
» Requires stopping SAN I/O, removing fNIC module dependencies, and removing and reloading the fNIC module .
» Not possible with the Boot from SAN configuration .
» Changes are nonpersistent across reboots .
• Run Time
» Nondisruptive .
» Changes apply only to newly discovered LUNs after modification .
» Changes are nonpersistent across reboots .
3 © 2014 Cisco and/or its affiliates . All rights reserved .