CTM LYNG microsafe mKomfy 1.8 16R Installatie-instructies Gebruikersinstructies - Pagina 5
Blader online of download pdf Installatie-instructies Gebruikersinstructies voor {categorie_naam} CTM LYNG microsafe mKomfy 1.8 16R. CTM LYNG microsafe mKomfy 1.8 16R 12 pagina's.

Alarmsignal
Alarm signal:
Cause:
Action:
Alarm signal:
Cause:
Action:
Alarm signal:
Cause:
Action:
Alarm signal:
Cause:
Action:
Alarm signal:
Cause:
Action:
Alarm signal:
Cause:
Action:
EMERGENCY MODE
In the event of problems with the cooker guard which you are unable to resolve,
you may activate the emergency mode, which will allow power to the cooker
for 12 hours (can be repeated for a further 12 hours).
NB: All safety functions are deactivated in this period. Use the time to contact an
electrician who will be able to resolve the problem.
To activate the emergency mode:
Turn the cooker fuse off and on three times at intervals of at least
1 second for a period of 10 seconds.
One (1) light and sound signal every 15 seconds for
5 minutes.
Cooker Guard warning that timer is in last 5 minutes.
Press control button to restart timer.
Two (2) light and sound signals every 5 minutes.
Battery change necessary.
Change batteries. NB: Make sure you have new
batteries to hand first (3 x AA).
Two (2) light and sound signals and the cooker shuts
off 10 min after use.
Battery change necessary.
Change batteries. NB: Make sure you have new
batteries to hand first (3 x AA).
Three (3) light and sound signals every 5 seconds
and a steady red light between signals.
Overheating.
Reduce temperature, or press control button
to temporarily approve high temperature.
Three (3) light and sound signals every 30 seconds.
Excess temperature continuing after shut-off.
Reduce temperature, or press control button.
Five (5) light and sound signals in the course of
5 seconds.
Anti-tamper function detects that sensor has been
removed from bracket.
Replace sensor in bracket and press control button.
Everyday use