Step 4: Loosen the splice bars from their
shipping position and slide them out to half
way. Tighten the splice bars.
Step 5: Slide the upper track section onto
the lower track section. Tighten the splice
bar set screw bracket to lock tracks together.
The tracks will not slide together if the set
screws protrude beyond the splice bar.
Step 6: Attach track brackets to the side of the
top track section. Hand tighten.

SLACK CABLE RESET PROCEDURE

Step 1: During shipping, the slack cable device may engage and need to be
reset.
shaft and rotate clockwise. This will slowly inch the unit up the track.
If you see the lift begin to move uphill or hear a click, that will tell you that the
slack cable has reset.
Rubex Stair Lift Install Manual | www.Ameriglide.com | 866-378-6648
10 //
16
Step 2: With the unit and upper track section installed
and power cable unplugged, you will use the hand
crank to turn the motor belt that turns the cable drum.
The illustrations show overhead and cut-away
views of the unit.
Step 3: Place the manual hand crank onto the motor
11819 P/N: 16169 Rev D
CAUTION:
Do not put
your fingers
between the
track sections
at any time as
injury could
occur.