2 – Installation
Dante network Ethernet port
Control network Ethernet port
*Note: The CommandHub has many other ports than listed above but only the two Ethernet ports are required. The
other ports and connections can safely be ignored.
The CommandHub can be mounted in several locations. The unit can sit on top of a table or shelf. There are also
mounting holes on the underside allowing the CommandHub to be permanently mounted on virtually any surface and in
any orientation. The unit can even be simply hung off a spare power outlet!
*Note: All wiring connections to the CommandHub should be completed before applying power to it.
2.1 – Supplying Power
The CommandHub comes with a power module that can be detached. The CommandHub can either run with the power
module attached or the power module can be separated and used as a separate power supply.
To power the CommandHub with the power module attached to the main module, fit the figure-8 power adapter to the
power module and use the figure-8 mains cable from the mains outlet to the CommandHub.
Further power options are provided if the power module is separated from the main module, with a DC power cable
(supplied) then used to connect the two modules together. The power module can then either be used as a wall wart by
attaching the mains adapter to it and plugging it directly into a mains outlet, or as a brick-type supply by attaching the
figure-8 power adapter and using the figure-8 power cable to connect to the mains outlet.
*Note: The CommandHub also includes blanking plates to cover the unused connections if the power and main module
are separated.