BX308 XP Gas Detection Controller
Controls & Navigation
Warmup
Duomo
SN 000846
g
23/Au /22
== BX308XP
v.4.2 ==
Countdown: 90
This display appears when BX308xp is powered up with a 90
second warmup countdown, Main Screen is then displayed.
Initial Screen
SN 00084
23/Au /22
State
Sensor 01
Exp 020%
00.0%LEL __________
ENTER - Sensor display lock ON/OFF
: Locked sensor display
- : Cycles active sensors every 8 seconds
ENTER (HOLD 5 seconds) - Access MAIN MENU
◄► - Accelerate current sensor being displayed
On Display
•
Display has Registration number
•
Date & Time
•
Work State
•
Currently monitored sensor
•
Target gas
•
Explosive or Toxic sensor
•
L.E.L or ppm sensor value
•
Bar graph of gas level
ENTER Password
Insert Password
0 1 2 3 4 5 6 7 8 9
◄► - Choose password digits
ENTER - Select digits
Successful password input displays MAIN MENU.
Time Settings
Input Settings
General Functions
Exit
t: 01905 797989
e: [email protected] | w: www.duomo.co.uk
Power
Pre Alarm
Battery
Main Alarm
OL Probes
Exit Alarm
10:45
OL Battery
Siren Status
Fault
Power
Pre Alarm
Battery
Main Alarm
g
OL Probes
Exit Alarm
11:44
OL Battery
Siren Status
Fault
Power
Pre Alarm
Battery
Main Alarm
OL Probes
Exit Alarm
OL Battery
Siren Status
Fault
(Default password is 1234)
Power
Pre Alarm
Battery
Main Alarm
OL Probes
Exit Alarm
OL Battery
Siren Status
Fault
Main Menu
Time Settings
Input Settings
General Functions
Exit
▼▲ - Choose menu option
ENTER - Select option
Time Settings
Date
g
23/Au /22
◄► - Select (Day/Month/Year or Hour/Minute) option
ENTER - Increment selected date or time
ENTER (HOLD) - Cycle through available options much
quicker
Select to return to MAIN MENU
Input Settings
Sensor Settings
Sensor Configuration
1 2 3 4 5 6 7 8
◄► - Select Sensor
ENTER - Change selected sensor between
Explosive
Toxic
Oxygen
CO2 sensor
No connected sensor
Continue to Memory
Memory Settings
Probe settings
Memory ON
Insert Password
0 1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
◄► - Select Sensor
ENTER - Select Memory ON/OFF
(OFF for toxic sensors only)
ON - Controller requires manual reset (RESET button)
OFF - Controller Auto resets (<50ppm)
Return to Probe Settings
Continue to Pre Alarm
8
Power
Pre Alarm
Battery
Main Alarm
OL Probes
Exit Alarm
OL Battery
Siren Status
Fault
Power
Pre Alarm
Battery
Main Alarm
Time
OL Probes
Exit Alarm
14 : 36
OL Battery
Siren Status
Fault
Power
Pre Alarm
Battery
Main Alarm
OL Probes
Exit Alarm
OL Battery
Siren Status
Fault
Power
Pre Alarm
Battery
Main Alarm
OL Probes
Exit Alarm
OL Battery
Siren Status
Fault