Abacus Electric Evolve Sonix Podręcznik użytkownika - Strona 7
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla System bezpieczeństwa Abacus Electric Evolve Sonix. Abacus Electric Evolve Sonix 10 stron. Wireless gsm alarm
1#0#
Deactivation* (all the sensors don´t work)
Switching on the warning tone for the
21#1#
activation of the external alarm
Switching on the warning tone for the
22#1#
activation of the internal alarm
Switching on the warning tone for the alarm
23#1#
deactivation
27#(00-
Alarm delay (10 seconds)
99)#
The delay cannot be set for the sensors that work continuously as e. g. the smoke sensor ot the SOS button
3#1#
Immediate sound signal
4#1#
Listening activation (the phone button)*
11#1#
Activation of siren during the alarm *
12#1#
Sending SMS during the alarm *
15#1#
Dialling the number during the alarm *
Deactivation of the relay connection by 3
16#1#
minutes during the alarm *
30##
Displaying the activation/deactivation state of each of the zones (only via the SMS commands)
31#--#
Change the password. Entering the new password (1-6 bit).
38#--#
Alarm activation for the zone (wireless zones: 1-16; wire zones: 21-23) Note: for each zone activation
Alarm deactivation for the zone (wireless zones: 1-16; wire zones: 21-23) Note: for each zone
39#--#
deactivation
50##
Displaying the numbers preset to the alarm main drive (controlling only via SMS)
51#--#
Phone number of the first group (0-15bit)
53#--#
Phone number of the third group (0-15bit)
55#--#
Phone number of the fifth group (0-15bit)
80##
Displaying the preset SMS
81#--#
The first group message (0-24bit)
83#--#
The third group message (0-24bit)
85#--#
The fifth group message (0-24bit)
87#--#
The seventh group message (0-24bit)
90##
Displaying the output state
91#1#
Output 1 setting to high
92#1#
Output 2 setting to high
93#1#
Allow the phone call (output 3)
94#1#
Relay setting to interconnect
95#1#
Set the alarm at opening input 1
96#1#
Set the alarm at opening input 2
97#1#
Set the alarm at opening input 3
Switching off the warning tone for the
21#0#
activation of the external alarm
Switching off the warning tone for the
22#0#
activation of the internal alarm
Switching off the warning tone for the alarm
23#0#
deactivation
28#(00-
Setting for delay (figure: 00-99)
99)#
3#0#
Sound turning off
4#0#
Listening turning off (the phone button)
11#0#
Turning off the siren during the alarm
12#0#
Not sending SMS during the alarm
15#0#
Just the alarm without dialling the numbers
Activation of the relay connection by 3
16#0#*
minutes during the alarm *
52#--#
Phone number of the second group (0-15bit)
54#--#
Phone number of the fourth group (0-15bit)
82#--#
The second group message (0-24bit)
84#--#
The fourth group message (0-24bit)
86#--#
The sixth group message (0-24bit)
91#0#
Output 1 setting to low
92#0#
Output 2 setting to low
93#0#
Forbid the phone call (output 3)
94#0#
Relay setting to disconnect
Set the alarm if the input line 1 is grounded
95#0#
(Gnd)*
Set the alarm if the input line 2 is grounded
96#0#
(Gnd)*
Set the alarm if the input line 3 is grounded
97#0#
(Gnd)*
48