Archer SR9 Instalacja, obsługa i konserwacja
Przeglądaj online lub pobierz pdf Instalacja, obsługa i konserwacja dla Kontroler Archer SR9. Archer SR9 6 stron. Automatic switchover
Model SR9 Automatic Switchover
General:
The Archer Instruments Model SR9 Automatic Switchover vacuum regulator
is designed for use in pairs, with one unit connected to an on-line gas cylinder / gas
source and the other connected to a standby cylinder / gas source. The SR9 can also be
used in the same way with multiple units connected to multiple standby gas sources.
Safety:
When working with chlorine, always use caution and follow applicable safety
procedures. General safety considerations:
* Store Chlorine separately from Ammonia.
* When using chlorine, avoid locations that expose the cylinder and equipment to direct
sunlight.
* Do not apply heater or heat source directly to chlorine cylinders.
* 150lb (upright) cylinders: Always keep cylinders upright and ensure the steel valve
cap is in place when moving cylinders. Once cylinder is in place, a safety chain should be
used to secure the cylinder.
* Ton Containers: Use appropriate handling equipment when moving ton containers.
When readying ton container for use, ensure valves are aligned vertically. The top valve
accesses gaseous chlorine and the bottom valve accesses liquid chlorine. The bottom
valve should never be touched unless your system employs a chlorine heat exchanger
(evaporator) designed expressly for use with liquid chlorine. When drawing gas from ton
containers an appropriate ton container adapter & drip leg must be used (also available
from Archer Instruments).