Menu 3 - Remote start

M e n u
One-chirp setting
Item
1
Engine checking: Virtual Tach
Remote start runtime: 12 mins
2
3
Parking light output: Flashing
Cranking time: 0.6 sec
4
5
Activation pulse 1
2nd Ignition/Acc output: Ignition
6
7
Acc state during wait-to-start Off
2nd status output: Normal
8
9
Anti grind: On
Diesel timer: Wait-to-Start input
10
11
Timer mode run time: 12 min
Timer mode: Timed starts
12
13
Short run (turbo): 1 min
*Additional settings using the Bitwriter®

Menu 3 - Descriptions

1. Engine Checking Mode
1.
Virtual Tach: battery voltage drop/rise during cranking determines when the starter output is released. During runtime, constant voltage
level is monitored to determine if the engine is running
2.
Voltage: starter output during cranking is a programmed duration (Set in Cranking Time). During runtime, constant voltage level is
monitored to determine if the engine is running
3.
Off: starter output during cranking is a programmed duration (Set in Cranking Time). The remote start will keep the ignition/accessories
active for the programmed runtime whether the engine is running or not
4.
Tachometer: tachometer input signal during cranking and runtime to determine when the starter output is released and if the engine is
running.
2. Run Time
12/24/60 minutes: sets engine runtime during normal remote start operations
3. Parking Light Output
1.
Flashing: the lights will pulse on/off during remote start
2.
Constant: the lights will turn on solid during remote start.
4. Cranking Time
0.6/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0 seconds: determines the starter output duration during cranking for the 'Voltage' and the
'Off' Engine Checking Mode options
5. Activation Pulse Count
1/ 2 pulses: sets the number of remote control commands received or Activation Input required to activate and de-activate remote start
6. 2nd Ignition/Accessory Output:
This will allow the PINK/WHITE to be used as a 2nd ignition or an accessory. The default is 2nd ignition.
7. Accessory State During Wait-To-Start Off/On:
This feature will allow the selection of the accessory output to be ON or OFF during wait-to-start.
8. Status 2 Output (Dark Blue H2/10 wire)
1.
Status Normal: the output will activate before the ignition outputs turn on, and de-activate after they turn off during remote start
14
Two-chirp setting
Voltage(2), OFF(3), Tachometer(4)
24 min, 60 min*
Constant
0.8, 1.0, 1.2, 1.4, 1.6, 1.8, 2.0, 4.0 second
2
Accessory
On
Rear defogger: latch 10 min.
rear defogger pulse
Off
Timed 15 , 30 ,45 seconds*
3, 6, 9, min*
Temp starts
3,5, 10 min
© 2012 Directed. All rights reserved.