alphatronics AlphaVision CP 508 Podręcznik użytkownika - Strona 6

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Panel sterowania alphatronics AlphaVision CP 508. alphatronics AlphaVision CP 508 6 stron.

still read within the historical overview in which zone the alarm occurred.
If a 24-hour zone went into alarm, all alarm indicators will be turned off by disarming, even if the
control panel is disarmed already.

6. PANIC/HOLD-UP

The installer can programm one of following possibilities to activate a panic/hold-up alarm:
<*>+<#>
by pressing both keys <*> and <#> simultaneously, a silent alarm will be transmitted
to the central station. No indoor or outdoor alarmindicators will be activated.
duress
if threatened during arming/disarming a hold-up message can be transmitted to the
central station by entering the duress-code. The duress code is the normal PIN-code
with the last digit of the PIN-code incremented by 1. So, instead of entering 4444,
4445 is the duress-code and will cause a hold-up message to be transmitted. Note: if
the last digit of the "normal" code is a 9, then a 0 has to be entered if duress code has
to be used, so if the PIN-code is 6789 then 6780 has to be entered to force the hold-
up message to be transmitted.
hold-up button if a hold-up button is implemented, a hold-up or panic alarm can be caused by
pressing this button. Depending on the installation programming an outdoor or indoor
alarmindicator can be turned on aswell. The alarm will always be visible on the
display as zone alarm.

7. DEFAULT VALUES

PIN-codes:
system supervisor
user
quick arming code
authorization

8. DISPLAY MESSAGES

Following indications can be shown on the display::
AL
alarm in zone
bP
while arming a zone was open (instant or 24-hour)
C
entering digits while programming usercode
C2
programm 2-digit quick-arming code
C4
programm system supervisor PIN-code
CA
programm usercode authorization
Cu
programm user PIN-code
EE serious system malfunction
FC invalid PIN-code entered
iS
isolate zones
LB low battery
Lt
walktest
oP
valid PIN-code entered
oo
case not closed correctly
Sb
sabotage alarm in zone
Manual CP-508 versie 2.5
4444
not programmed
not programmed
all PIN-codes valid for section A, B and C, codes cannot be
used for programming, sections cannot be armed/disarmed
seperately, isolation of zones not allowed.
September 17th 1993
pg. 6