Instruction Manual - PM1 Tracker

2. START/STOP OF THE UNIT

Hold the Selection Button for 2s. to start the PM1 Tracker.
The Main Menu appears.
Here you are able to select the different modes: PM 1ndex, Realtime
and Monitoring (this mode is only available if communications
settings are activated), Settings and Power Off of the unit.
The PM1 Tracker stops automatically if:
• PM 1ndex measurement ends and/or is idle for 20mins
• Realtime measurement launched and/or is idle for 10mins
• Monitoring mode launched and no battery charge for 2hours.

3. PM 1NDEX MODE

The PM 1ndex measurement displays the Indoor Air Quality after
15 minutes of data collection.
During this time:
• The Operational Indicator LED will blink in yellow
• After every minute, an intermediate result is displayed in the
Information Panel
A gauge at the bottom of the Information Panel indicates the
status of the test
• Hold the Selection Button to stop the measurement
• Press the Selection Button once during the measurement
process to display an intermediate result.
At the end of the test, the final result is displayed in the Information
Panel and the Operational Indicator LED will blink in green.
The result is still available for 20 minutes with a short press.
If the mode ALWAYS-ON is activated, and the unit is connected to
the main supply, the measure will start again after 10min.
4
Camfil - Clean air solutions