Akw M11 DigiPump Instruções de instalação e cuidados do utilizador - Página 4

Procurar online ou descarregar pdf Instruções de instalação e cuidados do utilizador para Produto de canalização Akw M11 DigiPump. Akw M11 DigiPump 20 páginas.

Akw M11 DigiPump Instruções de instalação e cuidados do utilizador

Mechanical And Plumbing Installation

Positioning
The AKW M11 DigiPump shower waste water pump must be installed by a
suitably qualified, competent person eg. NIC EIC, in accordance with current IEE
Wiring Regulations (BS7671), building regulations and local by-laws.
This product is rated at IP45 and suitable to be installed in Zone 1 or Zone 2
of a shower room only if these instructions are fully complied with.
The unit must be located away from the direct line of water jets.
Note: Zone 1 lies above zone 0 and below 2250mm (88in) vertically above a shower
tray or wet floor area.
The perimeter of zone 1 of a wet floor is within a 1.2 metres (47in) radius of the
shower head position. Consult BS7671 for further clarification.
FOR GUIDANCE ONLY- PLEASE REFER TO BS7671 FOR FURTHER DETAILS
4
© 2012 AKW Limited