Akw M11 DigiPump Instructies voor installatie en onderhoud - Pagina 4

Blader online of download pdf Instructies voor installatie en onderhoud voor {categorie_naam} Akw M11 DigiPump. Akw M11 DigiPump 20 pagina's.

Akw M11 DigiPump Instructies voor installatie en onderhoud

Mechanical And Plumbing Installation

Positioning
The AKW M11 DigiPump shower waste water pump must be installed by a
suitably qualified, competent person eg. NIC EIC, in accordance with current IEE
Wiring Regulations (BS7671), building regulations and local by-laws.
This product is rated at IP45 and suitable to be installed in Zone 1 or Zone 2
of a shower room only if these instructions are fully complied with.
The unit must be located away from the direct line of water jets.
Note: Zone 1 lies above zone 0 and below 2250mm (88in) vertically above a shower
tray or wet floor area.
The perimeter of zone 1 of a wet floor is within a 1.2 metres (47in) radius of the
shower head position. Consult BS7671 for further clarification.
FOR GUIDANCE ONLY- PLEASE REFER TO BS7671 FOR FURTHER DETAILS
4
© 2012 AKW Limited