2.3.3. Preparing the sensor
Unsnap cover and
remove upwards
Fig. 9
1
Screw-on cover (230V
device)
2
Cover with rain sensor
3) Cover Snaps
4
Bottom part of housing
The sensor cover snaps in on the left and right along the bottom edge (see Fig.). The
cover of the 230V model is also screwed on top. Remove the cover. Proceed carefully,
so as not to pull off the wire connecting the PCB in the bottom part with the rain sensor
in the cover (soldered cable connection in case of 230 V AC version, cable with plug in
case of 24 V DC version).
Lead the cable for the voltage supply and bus connection through the rubber seals on
the bottom of the device and connect Voltage L/N and Bus +/- to the terminals provid-
ed.
For 24V devices the connection cable must be plugged in between the cover and circuit
board.
Rain/Wind Sensor KNX RW • Status: 19.08.2013 • Technical changes reserved. Errors reserved.
7
Installation and commissioning
Fig. 10
Remove the cable shielding under the circuit
board and only feed the connector cables up-
wards through the openings in the circuit
board.
1
2
3
4