AFL OptiNID 500 Manual de instruções de instalação - Página 3

Procurar online ou descarregar pdf Manual de instruções de instalação para Invólucro AFL OptiNID 500. AFL OptiNID 500 8 páginas. Optical demarcation closure

AFL OptiNID 500 Manual de instruções de instalação

PACKAGE CONTENTS: ACCESSORIES

Single Fusion Splice Chip Kit
Security Cover
Mounting Screws

REQUIRED TOOLS

216-Style Socket Tool
Flat head Screwdriver

ADD-ON COMPONENTS

Compression Fitting Kit
Splice Chip Kit
Pigtail Kit

CLOSURE MOUNTING

1. Using local engineering practices, determine the mounting position of the closure on the wall.
2. Using the provided mounting screws, secure the closure to the wall.
Note: When mounting to a pole, the two mounting tabs located on the back of the closure
are designed to accept a Del Tec strap.

LOCK AND UNLOCK EXTERIOR DOOR

1. Using a standard 216 style tool, or similar, loosen the
screw located on the right side of the closure door.
Do not remove this screw from the closure doors.
2. Press the tab located above the hex screw in to open
the closure. (Figure 1)
Note: A pad lock, not provided, may be utilized if
additional security is desired.
INSTALLATION INSTRUCTIONS
OptiNID
© 2017, AFL, all rights reserved. Revision A, 2.16.2017
Specifications are subject to change without notice.
3
500 Optical Demarcation Closure
®
Figure 1
Tab
Screw