Fujitsu PRIMERGY TX300 S3 Manual do suplemento de serviço - Página 21
Procurar online ou descarregar pdf Manual do suplemento de serviço para Servidor Fujitsu PRIMERGY TX300 S3. Fujitsu PRIMERGY TX300 S3 47 páginas.
Replacement routines
I
The Power backplane in the floorstand model is positioned directly under
the top cover and it makes sense to lay the server on a table with the
uncovered side facing upward. Place the server in such a way that the
feet can project over the edge.
Figure 3: Removing the PS safe guard
V
CAUTION!
Before removing the PS safe guard, the server must be disconnected to
the main voltage because of energy hazard on the Power backplane.
Ê Remove the screw (see the circle) and take out the PS safe guard.
Ê Disconnect all power cables from the Power backplane.
Ê Remove the four screws of the PS cage at the rear side of the server and
pull out the PS cage.
TX300 S3
Replacing the Power backplane
Service Supplement
21