CAB HS 120 Manual do operador - Página 16

Procurar online ou descarregar pdf Manual do operador para Fabricante de etiquetas CAB HS 120. CAB HS 120 18 páginas. Label dispenser

16
4
Operation

4.2.3 Setting Speed

 Check the chosen speed by means of the LEDs (5 / 6).
 Touch button

4.2.4 Resetting Counter

 Touch button

4.2.5 Error Treatment

If no label is detected by the present sensor within 5 seconds after starting
the peel-off operation, the label transport will be stopped and an error will be
signalized :
The counter display is flashing.
The LED for the chosen operation mode is flashing.
Cause
Out of labels
The peeled label does not activate
the present sensor
Material transport is interrupted
Table 2
 Rectify error.
 Continue operation by touching button
start signal or releasing the present sensor manually.
for changing the speed setting.
for resetting the counter.
Fault Correction
Remedy
Insert new material
Adjust present sensor
Reduce speed
Remove material from rewinder
respectively sending a
16