OPERATING TEMPERATURE
The maximum ambient operational temperature is between -40 °C and +85 °C.
NOTE: Depending on ambient temperature, handset warm up may take approximately 30
seconds at 20 °C and approximately 1 minute at 0 °C for the 24V ECU.
BATTERY VOLTAGE
The voltage supplied to the ECU, which in turn powers the handset, is supplied by the
vehicle battery.
For a 12V device, the vehicle battery voltage can range from 9V to 18V. For a 24V
device, the vehicle battery voltage can range from 16V to 36V.

USING THE ALCOLOCK V3 DEVICE

STARTING THE MOTOR

Wait...
Menu(hold)
Blow for
5 seconds
Menu(hold)
INSTRUCTION MANUAL
1. Turn the handset power on by pressing the right button. The
Wait message is displayed during warm-up.
Alternatively, the power can be turned on by switching the
ignition key on and off.
NOTE: The key must be in the off position before moving on.
2. The handset displays the message Blow for 5 seconds when
it is ready for a breath test. The warm-up time is longer in
colder temperatures.
NOTE: Do not store the mouthpiece to be used in a cold area.
This causes condensation in the mouthpiece and increases the
opportunity for water to enter the handset.
3. Insert a new mouthpiece. Using a new mouthpiece practices
good hygiene and ensures a good breath sample.
NOTE: Do not eat, drink or smoke anything for at least 10 minutes
before taking a test. This could contaminate the breath sample.
4. Blow into the mouthpiece moderately and continuously while
listening for a tone indicating proper breath flow. If you are not
blowing correctly, a message is displayed providing instructions
on how to blow correctly.
5. Stop blowing when the handset tone stops. The Wait message
is displayed as the breath sample is analyzed.
6. The handset beeps and displays the result:
2