Unoccupied Stalls and Cows without Tags.
In these situations the Auto-ID control cannot obtain a valid tag read and will require immediate attention. The system will
read and feed properly tagged cows up to the vacant stall or untagged cow then Scanning will cease.
Proceed as follows:
Press the Scanning Switch fitted to the bottom of the control; This will start the scanning process.
Starting at stall(1), the MicroMarque3S will attempt to read an ear tag at each stall on that side. The stall
being read currently will be displayed in the STALL/SIDE window and the message 'ScAn' will
flash in the Cumulative Totals window.
With each successful tag read, the MicroMarque3S will access the cow's record and deliver the appropriate
amount of feed.
The scanning process will cease when the system encounters an empty stall or a cow without an ear tag- an
unsuccessful read. Indicate that you have recognised the problem by:
Press STEP key. The system will 'remember' that there is a fault at that stall and continue to scan and
deliver feed to the remaining stalls. When scanning is complete, the message 'ScAn End' will be
displayed:
Press the ATTN key. The display will now have 3 underscore prompts in the COW
NUMBER window, the message 'ntg' (No Tag) in the RATION window and the stall at which the
unsuccessful read occurred in the STALL/SIDE window.
Three options are now available:
1: If the stall is occupied by an untagged cow that has a record, its number may be keyed in and it
will be fed in the usual way.
2: If the stall is occupied by an untagged cow that does NOT have a record, it may be fed a ration
keyed into the control. However, the ration value will be added to the Cumulative Feed Total only.
3: If the stall is unoccupied or occupied by a cow that does not require feeding, it may be skipped.
These options are detailed on the following page.
Cow
Program
HERRINGBONE
AUTO-ID
OPERATION: 8
+
Shift
Cumulative Totals
Step
Attn
Ration
Yield/Flags
RESET
Cancel
!
The buzzer will NOT sound for a
stepped stall.
Stall/Side
DELETE
Change