Andisoon Measure T635 Series Руководство пользователя - Страница 3

Просмотреть онлайн или скачать pdf Руководство пользователя для Промышленное оборудование Andisoon Measure T635 Series. Andisoon Measure T635 Series 10 страниц. Hydrogen refueling nozzle

I. Product Introduction
This hydrogen refueling nozzle is designed into an automatic locking
structure. After the head of the hydrogen refueling nozzle and the
hydrogen refueling port are connected in place, the internal claws of the
hydrogen refueling nozzle automatically block and lock the hydrogen
refueling port, so as to form a reliable mechanical connection between the
hydrogen refueling nozzle and the hydrogen refueling port. After the
successful communication between the hydrogen refueling nozzle and the
on-board system, press the hydrogen filling button on the hydrogen
dispenser, and the high-pressure hydrogen flows to the on-board cylinder
at the rear end of the hydrogen refueling port through the hydrogen
refueling nozzle, so as to realize the function of vehicle hydrogen filling;
after filling, the hydrogen refueling nozzle can release the pressure of the
gas in the chamber of the hydrogen refueling nozzle through the valve
switch of the pipeline in the hydrogen dispenser. After the pressure relief,
manually slide the outer sliding sheath on the head of the hydrogen
refueling nozzle backward to separate the hydrogen refueling nozzle from
the hydrogen refueling port and complete the whole filling process.
2
4
1
3
1. Hose sheath 2. Nozzle head 3. Outer sliding sheath 4. Infrared receiver
module
1