Consolidated VYNIL-VAC ASP-1105 Руководство - Страница 5

Просмотреть онлайн или скачать pdf Руководство для Водяной насос Consolidated VYNIL-VAC ASP-1105. Consolidated VYNIL-VAC ASP-1105 6 страниц.

Consolidated VYNIL-VAC ASP-1105 Руководство
PROBLEM
1. Excessive noise.
2. Motor fails to develop full power
(low voltage).
3. Motor starts slowly and fails to
come up to speed.
4. Motor overheats and trips the
thermal overload.
5. Motor stalls, resulting in blown
fuses and tripped circuit
breaker.
6. Frequently blown fuses or
tripped circuit breaker.
7. Excessive impeller fan noise.
PROBABLE CAUSE
1. Motor bearings.
2. Circuit overloaded with other
appliances or motors.
Extension cord too short or too long, or
wrong gauge.
3. Low voltage.
Switch contacts not working properly.
Burnt capacitor.
4. Motor overloaded. Improper cooling air
restricted through motor or dust build-
up.
5. Voltage too low to allow motor to reach
operating speed.
Fuses or circuit breakers do not have
sufficient capacity.
6. Motor overloaded.
Fuses or circuit breakers do not have
sufficient capacity.
7. Loose or rubbing impeller fan.

Troubleshooting

SUGGESTED SOLUTION
1. Have motor checked by qualified
technician.
2. Do not use other appliance or motors on
the same circuit when using the Vinyl-Vac
System.
Increase the wire gauge size of your
extension cord(s).
3. Check voltage output with a voltmeter.
Have motor repaired or replaced by
qualified technician.
Have capacitor replaced by qualified
technician.
4. Check voltage output with a voltmeter.
Clean dirt on motor to provide normal air
circulation through the motor.
5. Check voltage output with a volt meter.
Install proper size fuses or breakers.
6. Install proper size fuses or breakers.
7. Consult qualified service technician to
repair loose or rubbing impeller. Check to
see if cap screw #523 is tight. The cap
screw holds impeller fan in place and has
a left hand thread.