Operation- Liner Installation
OPERATION
LINER INSTALLATION PROCEDURES
When using your Vinyl-Vac System on a new construction installation where there is no existing deck to place it close to the pool, we suggest
you go to any building supplier and buy a piece of 4" weeping tile, non perforated, 2-3 feet or whatever length you need to position your
Vinyl-Vac System away from the pool. Connect the other end to the Vinyl-Vac inlet.
We suggest 4" weeping tile because the ribs are shallow and rounded. After testing, doesn't restrict air flow, also its flexibility does not break
down after extended use and it's inexpensive.
We do not supply the weeping tile because it is too costly to package and ship and we would have to pass this expense on to you, the dealer.
"What if I have sand bottoms?"
When installing a liner in a pool with a sand bottom, keep the 4" pipe 1" from the sand bottom and drill four 9/16" holes in the side of the pipe,
2 holes on each side, not more than 6" from the bottom. This relieves the concentration of suction from the bottom of the pipe. The reason for
keeping the 9/16" holes low on the pipe is to keep the suction low on the pipe where the cove is at the bottom of the wall. The cove is the air
channel around the pool.
"What if I have foamed walls, how do I keep the foam from being sucked into
the pipe"
After positioning the Vinyl-Vac System cut a 6"-7" arch in the foam at the point of entry
for the pipe, as shown in Fig.6, before installing the liner.
After you're finished installing the sand bottom liner we suggest you tape the 9/16"
holes with duct tape to return full suction concentration to the bottom of the pipe so if
your next liner installation has ground water it will be able to pick it up.
FIGURE 6