WARRANTY INFORMATION
The Vinyl-Vac System has a full 1 YEAR WARRANTY on everything against manufacturer's defects except for the tube frame around it. It is
there to protect the machine. If tube frame gets broken, it has done its job. Note: If a weld breaks, fix it with a self-tapping metal screw.
Specific Vinyl-Vac System Safety Rules
When using the Vinyl-Vac System, follow these basic safety rules:
WARNING!: To reduce the risk of electric shock or injury...
1. DO NOT USE this Vinyl-Vac System as a water pump.
2. PLACE THE VINYL-VAC SYSTEM on a stable level surface.
3. DO NOT ALLOW the Vinyl-Vac System to be used as a toy. Close
attention is necessary near children.
4. DO NOT LEAVE the Vinyl-Vac System plugged when not in use.
5. TO AVOID INJURY FROM ACCIDENTAL STARTING, unplug
power cord before working on or checking any parts of the
Vinyl-Vac System.
6. DO NOT UNPLUG by pulling on the power cord. To unplug, grasp
the plug, not the power cord.
7. TURN OFF the Vinyl-Vac System before unplugging.
Specifications
Model..................................................................................................ASP-1105
Voltage ......................................................................................................120V
Amperage....................................................................................................7.4A
Cycle/Phase ................................................................................60Hz, 1 phase
ELECTRICAL INFORMATION
POWER SUPPLY
WARNING: YOUR VINYL-VAC SYSTEM MUST BE CONNECTED TO A 120V,
15-AMP CIRCUIT. FAILURE TO CONNECT IN THIS WAY CAN RESULT IN INJURY
FROM SHOCK OR FIRE. Your Vinyl-Vac System must be properly grounded. Not all
outlets are properly grounded. If you are not sure if your outlet is properly grounded,
have it checked by a qualified electrician.
WARNING: IF NOT PROPERLY GROUNDED, THIS VINYL-VAC SYSTEM CAN
CAUSE ELECTRICAL SHOCK, PARTICULARLY WHEN USED IN DAMP
LOCATIONS.
EXTENSION CORDS
The use of any extension cord will cause some loss of power. Use the chart in Fig.2
to determine the minimum wire gauge (A.W.G-American Wire Gauge) extension cord
needed. For circuits that are further away from the electrical circuit box, the wire gauge
must be increased proportionately in order to deliver ample voltage. Refer to chart in
Fig.2 recommended for wire length and size.
ON/OFF SWITCH WITH REMOVABLE SAFETY KEY
The On/Off switch (A) Fig.3 comes with a removable safety key (B). When the safety
key is removed from the switch (only in the Off position) and placed in a safe location,
unauthorized persons or children can't turn the switch to the On position. It is
recommended to always remove the safety key from the switch whenever the
Vinyl-Vac System is not in use.
RESET BUTTON (OVERLOAD PROTECTOR)
This Vinyl-Vac System comes with an overload reset button (C) Fig.3 (next to the
On/Off Switch). If the Vinyl-Vac System motor overheats, a safety mechanism stops
the motor automatically due to motor overheating or low voltage. Press the reset
button and restart the Vinyl-Vac System. If the Vinyl-Vac System does not restart,
wait 5 minutes to allow motor to cool down before restarting.
Warranty, Specific Safety Rules
8. DO NOT USE this Vinyl-Vac System if the power cord is damaged.
If your Vinyl-Vac System is not working as it should, has missing
parts, has been dropped and damaged, or dropped in water, have
it serviced by a qualified technician before using again.
9. DO NOT HANDLE PLUG of the Vinyl-Vac System with wet hands.
10. KEEP HAIR, LOOSE CLOTHING away from moving parts.
11. CONNECT THE VINYL-VAC SYSTEM to a properly grounded wall
outlet. See grounding instructions below in the Electrical
Information section.
12. EXTENSION CORDS in poor condition, or extension cords with an
inadequate wire gauge AWG rating (caliber of cord too small), can
pose fire and shock hazards. When using an extension cord, make
sure it is in good condition, see recommended extension cord wire
gauge AWG rating and length. See extension cord information
below in the Electrical Information section.
CURRENT CARRYING
GROUNDING PRONG
Tool's
Amperage
Rating
3-6
6-8
8-10
10-12
12-16
& Electrical Information
PROPERLY GROUNDED
120V OUTLET
PRONGS
FIGURE 1
Cord Size in A.W.G.
Cord Length in Feet
25
50
100 150
18
16
16
14
18
16
14
12
18
16
14
12
18
16
14
12
14
12
-
-
FIGURE 2
FIGURE 3