IMPORTANT SAFETY INFORMATION
1: The test button accurately tests the smoke alarm functions.
Do not use any other test method. Test smoke alarms weekly
to ensure proper operation.
2: If you're sure it isn't a real alarm, open windows or fan the air
around the smoke alarm device to silence it
3: Observe and follow all local and national electrical and
building codes for proper installation.
4: This smoke alarm is powered by AC 220~240V mains
voltage. The smoke alarm should only be installed by
a licensed, qualified electrician. Observe and follow all
local and national electrical and building codes to ensure
compliant installation.
5: This smoke alarm is not suited for connection to non-pure
sinusoidal power sources (e.g. derived from square-wave
invertors). If installing on off grid premises, please check the
supply is suitable.
6: Smoke alarms can only activate when they detect smoke
or detect combustion particles in the air. They do not sense
heat, flames, or gas. This smoke alarm is designed to give
audible warning of a developing fire. However, many fires
are fast - burning, explosive, or intentional, and others
are caused by carelessness or safety hazards. In these
circumstances, there may be insufficient smoke to activate
the alarm QUICKLY ENOUGH to ensure safe escape.
7: Smoke alarms have limitations. This smoke alarm is not
foolproof and is not warranted to protect lives or property
from fire. Smoke alarms are not a substitute for insurance.
Homeowners and renters should insure their lives and
property. In addition, it is possible for the smoke alarm to fail
at any time. For this reason, you must test the smoke alarm
weekly and replace unit every 10 years.
BATTERY REPLACEMENT
1. Remove the locking plug from between the bracket and the
base of the smoke alarm if fitted. (See Diagram 1)
DIAGRAM 1
2. Remove the alarm body from the bracket.
3. Squeeze the locking arms on the sides of the AC Quick
connector while pulling the connector away from the bottom
of the alarm.
4. After alarm has been removed, you can open the battery
cover and replace with a new battery. (See Diagram 2)
DIAGRAM 2
EMERALD PLANET HEAD OFFICE - SYDNEY Unit 2 / 29 Mitchell Road, Brookvale NSW 2100 Australia P 02 9466 6000
5. Close the battery cover.
6. Plug the AC QUICK CONNECTOR into the back of the alarm,
making sure that the locks on the connector snap into place.
The green LED will illuminate.
7. Fit the alarm body back onto the bracket and turn the alarm
body clockwise (See Diagram 3).
DIAGRAM 3
8. Insert the locking plug into the gap between the bracket and
the base of the smoke alarm if desired. (See Diagram 4).
DIAGRAM 4
Test the smoke alarm by pressing and holding the Test button,
the alarm should beep 3 times then release the button.
The unit will now go into Hush/Silence mode for 8 minutes.
During this period, the RED LED will flash once every 8
seconds. After 8 minutes, it will go into normal operating status
and flash once every 32 seconds.
If there's no sound when the test button is pressed, it
means that the smoke alarm is faulty or it has been installed
incorrectly, please refer to the "Troubleshooting" section.
CAUTION: TEST THE SMOKE ALARM FOR CORRECT
OPERATION USING THE TEST BUTTON WHENEVER THE
BATTERY IS REPLACED.
DO NOT INSTALL SMOKE ALARMS IN THE
FOLLOWING PLACES
1: Near appliances or areas where normal combustion regularly
occurs (kitchens, near furnaces, open fireplaces, hot water
heaters etc.).
2: In areas with high humidity, like bathrooms or areas near
dishwashers or washing machines. Install at least 10 feet
away from these areas.
3: Near air returns or heating and cooling supply vents. Install
at least 3 feet away from these areas. The air could blow
smoke away from the detector, interrupting its alarm.
4: In rooms where temperatures may fall below 5° or rise above
45°, or in humidity higher than 85%. These conditions could
reduce battery life or cause a false alarm.
5: In extremely dusty, dirty, or insect–infested areas influence
particles interfere with smoke alarm device operation.