7. Technical Parameters
Product Parameters:
Flow Rate
Type
(L/h)
500
MRS-4.5
※ Water treatment capacity per cycle is various according to the difference water quality of
different region. The standard testing conditions is: Water temperature:25 ℃ , Raw
waterhardness: 150mg/L(CaCO3).
Service Conditions:
Water Pressure: 0.15-0.6MPa;
Water Temperature: 5~38℃
Environment Temperature: 4~40℃
Relative Humidity:90%(25℃)

8. Installation

8.1. Installation Notice
※ The product is prohibited to be tilted or laid down during the transportation, installation and
usage.
※ Place the prduct on the flat surface that can bear the weight more than 300kg/㎡ . Besides,
there are water inlet and water outlet, drain pipeline and sewage in the workplace.
※ Generally, the products are installed in the villas, apartments, schools etc or connected with
the main water pipelines of other office and business premises; if installed outdoors,
protective measure should be taken to prevent it from freezing, sunburn and soaking.
※ The product should be kept off circumstances with alkaline and acid substance or gases in
case of corrosion.
※ The suitable pressure for softener is between 0.15Mpa and 0.6Mpa. If lower or higher than
the standard, a booster pump or a relief valve should be intalled to ensure the normal
operation of the equipment.
※ One place is recommended to install the system which causes the minimum loss in case of
water leakage.
※ Use reagent to measure the inlet water hardness, for the hardness is related to the softening
effect and softening cycle. This series of products should be used in those places where the
water hardness is lower than 450mg/L.
※ Make sure a check valve is installed between the device and water heater when a heating
stove or water heater is connected behind the device, in case the hot water reflux cause
damage to the internal system of the product.
※ Separate sewage is required for the drain of the device. There should be 5 to 10cm of space
between the drain pipeline and floor drain, in case the siphon causes damage to the valve by
the waste.(Installation refer to below picture)
Water Capacity
Per Cycle(L)
Water Capacity (L)
1200
Rated Total
Inlet/Outlet
320
3
Regeneration
Mode
3/4
Down-flow
Drain
1/2