※ Before installing the pipeline, please clean off the residual impurities and dust in the pipeline.
After the main water inlet is closed, connect it with the device.
※ All pipelines should meet the relevant regulations. The installation and connection should
comply with the local installation rules.
※ Keep a certain operation space for adding salt, cleaning an maintaining.
8.2. Installation and Connection
※ The pipeline connection and installation should be carried out in accordance with "Water and
Sewage Pipeline Construction Standards". The inlet/outlet connector and pipeline connector
should be installed on the same axis. Be sure not to install the positions of inlet and outlet
reversely.
※ The affiliated DLFC should be inserted into the drain outlet. The inlet, outlet pipeline,drain
line and overflow pipeline should be connected in sequence and make sure there are no
leakage of every joint. It is suggested to use hose pipe to connect the softener with inlet,
outlet, drain connector and overflow connector. (Attention: the pipe fittings and valves
should be made of 304 stainless steel, alloy copper forging, or high strength engineering
plastics, etc. The iron valves and pipe fittings are forbidden to use.)
※ It is suggested to install a manual bypass valve between the main water inlet and inlet/outlet
of the device, making it convenient for intallation and maintenance. (Refer to the below
installation illustration).
Valve A
Inlet
Valve B
Multi-functional Flow Control Valve
Brine Tube
Outlet
Valve C
Softened Water
To Water
Raw Water
Brine Tank
Drain Line
Flow Drain
4
Municipal Water
Supply
Pressure Tank
Softener
Well
pump
Restricted to Provate Wells
Well Water