OPTIONAL FBB5 SINGLE SPEED BLOWER INSTALLATION INSTRUCTIONS

Attention: Install blower assembly before connecting gas inlet
supply line.
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, if an external
electrical source is utilized. This appliance is equipped with
a three-prong [grounding] plug for your protection against
shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug. For an ungrounded receptacle,
an adapter, which has two prongs and a wire for grounding, can be
purchased, plugged into the ungrounded receptacle and its wire
connected to the receptacle mounting screw. With this wire com-
pleting the ground, the appliance cord plug can be plugged into the
adapter and be electrically grounded.
Label all wires prior to disconnection when servicing con-
trols. Wiring errors can cause improper and dangerous op-
eration. Verify proper operation after servicing.
NOTE: Junction box on right side of firebox must be pre-wired
at time of firebox installation for use with blower assembly. A
standard wall ON/OFF wall switch or optional SCV1 Variable
Speed Control Kit should be installed to activate power to the
Firebox, and control the operation of the FBB5 Blower assembly.
It is recommended that installation of the wiring be performed by a
qualified electrician. See Figure 13.
1. If installed, turn OFF gas supply to firebox/gas log.
2. If applicable, turn OFF electric supply to firebox.
All wiring should be done by a qualified electrician and
shall be in compliance with all local, city and state building
codes. Before making the electrical connection, make sure
that main power supply is disconnected. The appliance,
when installed, must be electrically grounded in accordance
with local codes, with the national electrical code ansi/nfpa
70 (latest edition).
Page 10
CAUTION
CAUTION
Figure 13
A factory installed junction box is located on the lower right
side of the firebox. Wiring must be fed to the junction box and
attached to the receptacle that is provided. From right side of
the firebox, remove the screw securing the junction box as-
sembly. Leave approximately 6 inches of wire in the junction
box for connection.
Attach black wire to one side of the receptacle and white wire
to opposite side of receptacle. The ground wire should be at-
tached to the green (ground) screw.
Install the receptacle into the junction box. Attach cover plate.
Attention: If installed, do not damage gas inlet supply line
when blower assembly is inserted into firebox. In some cases,
removal the gas inlet supply line may be necessary.
3. Determine which type of firebox you have prior to installation.
See Figures 14 and 15.
DELUXE
LOUVERED
MODELS
Figure 14
DELUXE
FLUSH
FACE
MODELS
Figure 15
39000-2-0820