MPPT solar charge controller X45/10
If the controller turns off the load due to under-voltage protection, over-current protection, short-
circuit protection or over-temperature protection, the load will automatically turn on again when the
charge controller exits the protection state.

9.4 Manual operation

If the load mode is set to manual, you can turn on/off the load output
manually via the Bluetooth app.

10. LED indicator

10.1 Explanation of LED display

status
LEDs
Green LED
On
Flashing (0.1 / 0.1s)
Flashing (0.5 / 0.5s)
Slow blinking (0.5/2s) Charging
Yellow LED
Off
On
Flashing slowly (0.5 / 2 s) Battery voltage is too low
Fast flashing (0.1 / 0.1s)
Red LED Off
On
Flashing (0.5/2s)
Fast flashing (0.1 / 0.1s)
01/2022
function
The solar module is correctly
connected but not charged
MPPT loading
Equal or reinforced charge
(Gel, wet or AGM battery)
Overvoltage protection
battery is normal
low voltage protection
Works normally
The output power is 0.
over temperature
Short circuit or over current protection