a-TroniX X45/10 Руководство по установке и эксплуатации - Страница 14

Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Контроллер a-TroniX X45/10. a-TroniX X45/10 16 страниц. Mppt solar charge controller

a-TroniX X45/10 Руководство по установке и эксплуатации
Machine Translated by Google
operation manual
MPPT solar charge controller X45/10

11.Troubleshooting

mistake
Charges are
not powered
Height
tension
at the
battery pole
false
system
voltage
Battery is after
a short
time empty
Battery
not
charging
page 14
status
low voltage protection
overcurrent or
load short circuit
over-temperature
protection
Overvoltage protection
ALL LEDs
flash quickly
Lower
voltage protection
Green LED
does not light up.
cause
The battery capacity
is low.
Overload or load
short circuit.
Control temperature
is too high.
battery over
voltage
>15.5V
(Li: CVT +0.2V)
The battery line or
battery fuse is damaged,
the battery has high
resistance.
The battery voltage is
not in the correct
range.
The battery has
insufficient capacity.
PV panel fault or the
pole connections are
reversed.
remedy
Charge battery via LVR.
Switch off all
consumers, eliminate
the short circuit,
reconnect the load
after 1 minute.
The controller turns off
the system until the
temperature falls below
60°C.
Check if other sources
are overcharging the
battery.
If not, the controller is
probably damaged.
Check battery performance
and battery fuse.
Discharge and charge the
battery to correct the
voltage.
Replace the battery.
Check the
panels and cables
links.
02/2022