Installation
requirements.
—Billi B–5000 system components
1. Underbench module
2. Dispenser tap upper with tubing
3. Dispenser base and mount
4. Barb locking bush
5. 4mm chrome screw and allen key
6. Large washer
7. Tube spring clamps x 3
8. 450mm flexible braided hose
9. Filter cartridge (installed)
10. Billi B–5000 User guide
11. Warranty certificate
—Determine unit location
Plan the installation. Dispenser tube
lengths, position of power and water outlets,
required air space around the underbench
module and access for service must be
considered before cutting tube lengths.
Refer to Diagrams 1, 2 and 3 for clearances
around the dispenser and unit. Unit must be
installed horizontally with plastic vent panel
facing to front of cupboard. The B–5000 is
designed for internal installation only.
—Water supply
The B–5000 must only be connected to a
cold water supply. A 15mm stop tap (not
supplied) is to be installed in an easily
accessible position within 450mm from
the B–5000 water supply inlet.
Supply pressure: 200 – 1000 Kpa
Supply temperature: 5°C – 30°C
DO NOT install with water that is
microbiologically unsafe or with water
of unknown quality without adequate
disinfection before the system. Systems
certified for cyst reduction may be used on
disinfected water that may contain filterable
cysts.
—Ventilation
The B–5000 requires cupboard ventilation,
adequate air space and an unobstructed
clearance of at least 25mm on each side
of the underbench unit. Door ventilation is
to be provided by spacing the door gap with
rubber stoppers.
—IMPORTANT
Insufficient ventilation will cause inefficient
refrigeration system operation, increasing
power usage.
—Power requirements
A single 10 amp standard power outlet
is required. B–5000 module is supplied
with 1 metre of flex cord and plug.
800mm
maximum
tube length
water tubing
deleted for clarity
150mm
minimum
clearance
power outlet
15 mm stop-tap
(installed by plumber)
340mm
Diagram 1
25mm
230mm
Diagram 3
60mm minimum
clearance
15mm min
180mm
Diagram 2
65mm
25mm
65mm
25mm
25mm
95mm
bench thickness
1mm-48mm
523mm
25mm
523mm
25mm