Access the console ports

The S55 system can be accessed directly through the console port at I/O side of the switch.

Access the RJ45 console port (RS-232)

NOTE: Before starting this procedure, be sure you have a terminal emulation program already installed on
your PC.
The RS-232 console port is labeled on the S55 chassis. It is in the upper right-hand side, as you face the
I/O side of the chassis.
Figure 7-1. S55 serial console port connector
RJ-45
Console Port
To access the console port, follow the procedures below. Refer to
Step
Task
Install an RJ-45 copper cable into the console port. Use a rollover cable to connect the S55 console port to a
1
terminal server.
Connect the other end of the cable to the DTE terminal server.
2
Default terminal settings on the console are set as follows:
3
• 9600 baud rate
• No parity
• 8 data bits
• 1 stop bit
• No flow control
Table 7-1
for the console port pinout.
Access the console ports
7
|