Allmatic BAXS900 Руководство - Страница 8

Просмотреть онлайн или скачать pdf Руководство для Блок управления Allmatic BAXS900. Allmatic BAXS900 13 страниц. For rolling shutters

Allmatic BAXS900 Руководство
8.5 SAFETY COAST / SENSITIVE EDGE (OPTIONAL)
BAXS900 is compatible with the optional wireless system T.CO.O - R.CO.O, whose fixed part R.CO.O is to be inserted on the main
board via the connector (see Fig. 5 page 3) or with the optional interface card to wire a resistive edge (only wired resistive edge), to
be inserted alternatively on the same connector (see Fig. 6 page 3). The installation of a safety coast allows to control the automation
via radio transmitter, according to EN12453.
To use the safety edge, place DIP 6 in position ON. Configure the wireless system by referring to the instructions of the system T.CO.O
- R.CO.O, keep the same at hand.
Resistive output 8.2kOhm
Direct polarity test enabled
The presence of an obstacle during the closing movement of the automation implies the immediate and total reopening of the same.
If at least one of DIP 1 or DIP 2 is in position ON (MAN PRESENT), the reopening will be partial (2 seconds of work). If a safety edge
is not used, place DIP 6 in OFF position.
For details regarding the functionality of the wireless system T.CO.O - R.CO.O please refer to the system instructions.

8.6 INPUT CONFIGURATIONS

BAXS900 can be controlled through:
Local controls (front panel)
Wired remote controls / wires (buttons, key selector or or other)
Radio transmitters
The opening control is configurable through DIP 1 (MAN OPENING PRESENT / IMPULSE OPENING) and through DIP 4 (OPEN
FUNCTION / GO FUNCTION). This configuration is binding on all control modes (central panel, remote control lines, radio
transmitters).
The closing control is configurable through DIP 2 (MAN PRESENT CLOSING/ IMPULSE CLOSING) and through DIP 4 (OPEN FUN-
CTION/ GO FUNCTION). This configuration is binding on all control modes (central panel, remote control lines, radio transmitters).
WARNING! In case the control unit identifies a problem on the safety devices (photocells, safety edges), the closing movement will
be allowed only by a local control (front panel) and in DEAD MAN mode.
WARNING! In case a safety edge is not used, the closing movement will be allowed only by the local control (front panel) or by the
remote closing control but only in DEAD MAN mode.
WARNING! Configure a type of use in accordance with EN12453, reducing the risk related to the use of automatic doors.
9. COURTESY LIGHT / WARNING
BAXS900 has an output dedicated to a courtesy light. In the BAXS900 the courtesy light is integrated.
COURTESY LIGHT FUNCTION: The light stays on for 2 minutes after each movement.
BLINKER FUNCTION:
1 second ON / 1 second OFF
0,5 seconds ON / 0,5 seconds OFF
0,25 seconds ON / 0,25 seconds OFF
10. RIDUZIONE DEL RISCHIO PER UN SISTEMA DI APERTURA MOTORIZZATO
Configure the system so that it complies with the minimum level of risk protection required by EN12453, depending on the type of
use you intend to make. If the system is controlled in DEAD MAN mode, the control devices shall be positioned at a minimum height
of 1,5 m and positioned outside the operating area in such a way that they are fully visible.
If the OPEN and CLOSE controls are located in an easily accessible area, use a key selector or similar device to prevent unauthorised
or inadequately trained persons from being used.
8 / 12
Opening test phase or pre-opening
Closing test phase or pre-closing
Safety Error
6-1622623 rev. 3