Whirlpool AWE 7515 Руководство пользователя - Страница 14

Просмотреть онлайн или скачать pdf Руководство пользователя для Стиральная машина Whirlpool AWE 7515. Whirlpool AWE 7515 19 страниц.

IFU-TL HR GB.fm Page 14 Friday, November 7, 2008 2:30 PM
If your washing machine has no time display, check which of the previously described
situations could be the origin of the fault and follow the corresponding instructions.
Black process 45.0° 100.0 LPI
Downloaded From WashingMachine-Manual.com Manuals
Indication on display
Red indication lamp
(if fitted on your
lights up
(in case your washing
machine has no
display: all lamps of the
programme sequence
indicator light up)
from "F02" to "F35"
(except "F09")
"Service"
machine)
"bdd"
Appliance stops during the programme.
"Drum flaps open" (the drum flaps have not been
closed properly).
Push the "Reset" button
and wait until the "Door open"
lid and close drum flaps, then select and start
desired programme again. If fault persists, notify our
After-Sales Service.
"Electrical module fault"
Select and start "Drain" programme or push
"Reset" button
"F09"
"Water level too high" (after programme
cancellation or false operating). Switch off appliance
and then switch it on again, select programme
"Drain" and start within 15 sec.
"FA"
"Waterstop fault"
Switch off appliance, pull out mains plug and turn
water tap off. Tilt appliance forward carefully to
allow collected water to flow out from the bottom.
Then:
• Plug in the appliance again.
• Turn the water tap on (if water immediately flows
into the appliance without the appliance being
started, there is a failure; turn off the tap and notify
After-Sales Service).
• Select and start the desired programme again.
"Fod"
"Overfoaming"
Too much foam interrupted the wash programme.
• Select and start "Rinse & Spin" programme
• Afterwards select and start desired programme
again, using less detergent.
If faults persist, unplug the appliance, turn off the
water tap and contact our After-Sales Service (see
next chapter).
GB 14
Description
Causes
Solutions
for at least 3 seconds
lights up. Open
for at least 3 seconds.
.