5542H402 Ed.03
4.- Installation
- Remove the bezels (1) from the device.
- Loosen the screws (2) with a 1/4 turn and open the cover (3).
- Drill the holes needed for the cable entry glands using the pre-stamped centres on the sides of the housing for
guidance. Fix the glands onto the device (4 and 5).
- Make 3 holes in the wall with the aid of the template included.
- Fix the device to the wall using the screws and plugs supplied (6).
- Insert the cables into the glands and wire the device following the diagram on page 6.
- Connect the battery (7) before closing the cover.
- Close the cover (3), insert and tighten the screws (2) and replace the bezels (1).
1
2
5
Ø Max. 20 mm
3
6
7
4
Ø Max. 25 mm
5