WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, PLEASE READ THE FOLLOWING:
1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number
listed in the warranty. 2.Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power
from being switching on accidentally. If the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag,
to the service panel. 3. Installation work and electrical wiring must be done by a licensed person(s) in accordance with all applicable codes and
standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent backdraft. Follow the heating equipment manufacturer's guideline and safety standards such
as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden
utilities. 6. Ducted fans must always be vented to the outdoors. 7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault
Circuit Interrupter) - protected branch circuit. 8. This unit must be grounded. 9. Never place a switch where it can be reached from a tub or shower.
Not for use in kitchens. 11. Install fan at least 2.5 m (8.2 feet) above the floor.
10.
do not use this fan with any solid-state speed control device. 13. The fan must not be installed in a ceiling thermally insulated to a value greater than
R40.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. This product is designed for installation
in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must be horizontal. ** DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 4. Please read
specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling.
OPERATION
Use an on/off switch to operate this fan. See "Connect Wiring" for details
PLAN THE INSTALLATION
1
. Do not use in a cooking area.
2. Two ways to connect ductwork to a factory-shipped unit
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner
MODEL: AP80RVL
12. WARNING: To reduce the risk of fire or electric shock,
.
.
INSULATION*
(Place around and
over Fan Housing.)
POWER
CABLE*
Seal gaps
around
Housing.
ROUND
DUCT*
*
Purchase
separately
BATHROOM FAN
ROOF CAP*
(with built-in
damper)
FAN
HOUSING
Keep duct
runs short
Seal duct
ROUND
joints with
ELBOW(S) *
tape.
.
WALL CAP*
(with built-in
damper)