FINISH CEILING WORK
1. A round ceiling hole 6 1/2 inches (165mm) diameter should be cut.
Seal any gap between the hole in the drywall and the fan with sealant.
2. Install the compact florescent bulb or LED bulb. Bulb not included.
3. The bulb housing can adjust up or down to accommodate different
bulbs. Unit is qualified with use of G24 adaptor and use of a GU24
.
bulb.
REPLACEMENT INSTALLATION
1. Remove the trim ring by detaching the springs.
2. Remove the screws as shown in the right.
3. Remove the lamp base.
4. Pull the duct system so that you can see the blower
system.
REPLACEMENT INSTALLATION
5. Remove the screws as shown on the right.
6. Remove the blower system from of the housing.
7. Replace the broken parts.
REPLACEMENT INSTALLATION
8. To replace the capacitance remove the wire panel, and then
replace the capacitance.
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
Fluorescent lamp
Joist
Hanger
bar
After finishing the ceiling job, fill gap between flange and ceiling with
caulk or other sealant to prevent air leakage.
Ceiling
Remove the screws
Remove the screws
Remove the screws
the screws
3
Blower system
Lamp base
Remove
Aero Pure AP80RVL
Lamp base
Wing nut
Wire Panel